General Specifications |
Enclosure |
Weather Proof, IP67, NEMA4 and 4X, O-ring Sealed |
Power Supply |
110/220V AC, 1Ph(50/60Hz) ¡¾ 10 %, 24V DC |
380/440V AC, 3Ph(50/60Hz) ¡¾ 10 % |
Control Power |
110/220V AC, 1Ph(50/60Hz) ¡¾ 10 % |
Duty Cycle (ON-OFF) |
S2 : Max 30 min(ITQ0350)/ Max 20 min(ITQ0500) |
Duty Cycle (Modulating) |
S4 : 50%, 1,200 Start/Hour(ITQ0350)/30%,800
Start/Hour(ITQ0500) |
Motor |
Induction Motor with Thermal Protector |
(High150¡É¡¾5¡É/Low97¡É¡¾15¡É) |
Limit Switches |
4 x SPDT (2 for Close, 2 for Open), 250VAC, 16A |
Torque Switches |
2 x SPDT (1 for Close, 1 for Open), 250VAC, 16A |
Travel Angle |
90 ¨¬ ¡¾ 10 % by external adjustable mechanical stopper |
Position Indication |
Continuous mechanical indicator with arrow |
Manual Override |
De-clutchable |
Self Locking |
Provided by double worm gearing (no brake) |
Mechanical Stopper |
1 each for each travel end (open & close), external & adjustable |
Terminal Block |
Screw and Lever Push Type (Spring Loaded) |
Cable Entries |
2 - PF3/4", NPT3/4", M25X1.5 |
Space Heater |
5W(110/220VAC) for anti-condensation |
Ambient Temperature |
BasicActuator:-20~+70¡É |
c/w Control Option:-10¡É~+60¡É |
Ambient Humidity |
90% RH Max (Non-Condensing) |
Technical Specification |
Model |
ITQ0350/0500 |
Rated Torque (Nm) |
350Nm (35Kg.m), 500Nm (50Kg.m) |
Operating Time (Sec) 110/220VAC (50Hz) |
31sec |
Operating Time (Sec) 110/220VAC(60Hz) |
26sec |
Operating Time (Sec) 24VDC |
31(ITQ0350)/37(ITQ0500) |
Max. Bore Size (mm) |
|
Key ( ) |
40mm |
Square ( ) |
34mm |
Motor Insulation Class |
F |
Amp Draw
|
Main Power |
50Hz(Running/Max) |
60Hz(Running/Max) |
110 Volt |
(1.72/2.87), (3.60/4.84) |
(1.80/2.87), (3.90/4.94) |
220 Volt |
(0.92/1.38), (1.50/2.32) |
(0.95//1.37), (1.60/2.34) |
380 Volt |
(0.32/0.77), (0.52/1.27) |
(0.32/0.74), (0.56/1.23) |
440 Volt |
(0.35/0.88), (0.55/1.52) |
(0.35/0.83), (0.58/1.36) |
24VDC |
(3.8/7.6), (4.6/8.0) |
No. of Handwheel |
14 |
ISO 5211 Mounting Flange |
ISO F10/12 flange |
Weight ( Kg ) |
20Kgs |
* Available Options: EX, WT, ALS, ATS, EXT, PK, CT, RPC, LP4, LM4, ICM1,II, BP
AC/DC Coverter
* DC 24V : Applicable to ITQ 0100~0500 |